PTTEP_PTO-A to PTO-D to NTM-A Project
Description
The cathodic protection current was determined by assuming 0.25% coating breakdown of the both the 8” pipelines 8.806 km in a soil resistivity 3000 Ohm-cm. The conservative calculations showed that in order to meet the CP current a total of 69 magnesium anodes will be needed. But as an extra precaution, 69 anodes(3 anodes/ TP) were decided to be installed. In the pipeline PTO-D to NTM-B at Kp.0+005, it was found that the CP current of the pipe was leaking to casing. The 3 magnesium anodes (3 anodes/ TP) were installed to prevent Casing to solve the problem.
Details
- OWNER: PTT EXPLORATION AND PRODUCTION PUBLIC CO.,LTD.
- CONTRACTOR: TESCO ENGINEERS CO.,LTD.
- LOCATION: Sukhothai, Thailand.