PWA Nakhon Ratchasima_Improvement and additional project.
Description
Galvanic Anode installation. The cathodic protection current was determined by assuming 2% coating breakdown of the pipelines (Diameter 700mm, 600mm) 10 km in a soil resistivity 2,500 Ohm-cm for 30 years protection. The conservative calculations showed that in order to meet the CP current a total of 283 magnesium anodes and 27 test stations will be needed. In the installation, the magnesium anode must be installed along the pipe line, the distance between 2 magnesium anodes as follow the design report.
Details
- Owner: Provincial Waterworks Authority Nakhon Ratchasima
- Contractor: Sam Prasit Company Limited
- Location: Nakhon Ratchasima, Thailand.
Project skills
- Installation complete
- Presentation